julian f5fd61984a Dingtian web password: set the admin's chosen password, verified
Fix two bugs found running the real assign flow: the saved web password
didn't match the device (login stayed admin/admin), and the UDP2 warning
never reached the admin.

Web password:
- Split the conflated field into webPassword (the DESIRED login; blank ->
  auto-generate) and webPasswordCurrent (the device's EXISTING password used
  as the old cred, default admin). Before, an admin typing a desired password
  made harden send it as the old cred -> rotation failed -> but the DB still
  saved the typed value, so it claimed a password the device never accepted.
- harden() now rotates current -> desired, VERIFIES by re-authenticating with
  the new password, and only returns secrets.webPassword on success (else a
  warning, nothing saved). Stores webPasswordCurrent for future re-runs.
- assign strips the typed webPassword/webPasswordCurrent and persists only the
  verified secret -- the DB never claims an unapplied password.

Warnings to the UI:
- assignDevice returns warnings[]; SetupWizard shows them in an amber
  "saved, but action needed" banner per category. This is how the admin learns
  the firmware wouldn't disable UDP2 (finish in the device web UI).

Verified on hardware: after harden the device rejects admin/admin and accepts
the chosen password; the UDP2 warning surfaces.
2026-06-15 12:26:34 +02:00

157 lines
10 KiB
Markdown
Raw Permalink Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
type: entity
tags: [parking, hardware, access-control, relay]
sources: []
updated: 2026-06-14
---
# Dingtian Relay Controller
A network **relay + input** board (the unit on hand is the **4-channel** variant: 4 relays + 4
inputs). Chosen to drive the entry/exit lane because — unlike the [[uhppote-controller]] — its
**inputs are independent of its relays**, which solves the [[access-controller-button-flow]]
blocker (a button on an input does not auto-open a relay; the host decides).
SDK: `dingtian/4ch/sdk_v2_0_0/` (programming manual, examples). MIT-compatible use; no vendor
runtime needed.
## ⚠️ The one gotcha: `input_link_relay`
By **default the device links each input to auto-fire its matching relay** (`input_link_relay: 1`,
`on_action_on: [[0],[1],…]` in the config) — i.e. the *same* auto-open problem as the UHPPOTE.
The difference: **it is configurable.** Set `input_link_relay: 0` (or clear the action mappings)
so an input only *reports* and the host commands the relay. **This config step is mandatory** for
the ticket-first entry flow. See [[autonomous-direction]].
## Protocol (Dingtian string — what we use)
Transport options: UDP/TCP string, UDP binary, HTTP CGI, Modbus, MQTT. We use **HTTP + UDP** —
see [[dingtian-vs-mqtt]].
- **Relay control — UDP *binary*, port 60000 (authenticated):** the driver's `pulseOpen` sends a
binary "write relay with jogging" frame carrying the `relay_pw` (the only relay option with a
password). Frame (verified on hardware):
`FF AA <session> 03 <pwLo> <pwHi> <relayByte> <jogLo> <jogHi>` — relayByte bit0=on, bits1-7=
channel-1; jog is 100 ms units, LSB-first; password 16-bit LSB-first (0 = none). The relay jogs
ON then auto-releases, so we never time a close ([[barrier-not-a-door]]). *(The simpler string
protocol — `1`+ch on, `2`+ch off, `11*` jog — works too but has no auth; we use it only for the
read-only status query.)*
- **Status / inputs — send `00`** → `「relays」:「inputs」:「count」`, e.g. **`0000:1111:4`** (4ch:
relays off, inputs high). `0` = OFF/Low, `1` = ON/High. Poll-based.
- **Input push — `input_link_url`:** device **HTTP POSTs to a host URL on input change** — the
push path for button events without a broker.
- **Discovery:** UDP multicast `224.0.2.11:60000`, send `\x05\xAA` (devices reply). Defaults:
IP `192.168.1.100`, UDP `60000` (binary) / `60001` (string).
- Binary protocol (port 60000) adds optional **password** + multicast; bitmask relay/input maps.
## Driver & config API
The `dingtian` driver ([[device-registry]]) implements three capabilities:
`AccessControlDevice` (relay pulse/latch over UDP), `InputDevice` (read inputs + poll-based
press/release events ~50 ms), and `PreconditionDevice` (below). Config fields include a separate
**`httpPort`** — the device's web/config API is on a configurable HTTP port (default **80**),
distinct from the UDP control port 60001.
### Precondition: input_link_relay must be OFF
The driver reads the device's JSON config (`GET /api/v2/config.cgi`) and **checks
`input_link_relay`**; if enabled it reports a fixable issue, and `fixPreconditions()` writes the
correction (`POST /api/v2/config_set.cgi`) — setting the flag to 0 and clearing `on_action_on`,
preserving everything else (network, etc.). This is the generic [[device-registry|precondition]]
capability: the app doesn't own full device config (that's the vendor web UI), only the few
settings our flow depends on.
> **Write gotcha (cost real debugging):** the GET config payload **omits** a `"command"` field, but
> the set endpoint **requires `"command":"setconfig"`** injected right after `"status"`. Without it
> the POST returns/looks like success but silently does nothing (and the device may reset). With it,
> POST returns `{"status":0}` and the change sticks. JSON node order must be preserved.
## Input push (no polling) — the chosen architecture
The device **pushes** button events to the backend; the backend decides. **No polling.** The
driver's `configureInputPush()` writes the device's `input_link_url` config to point each input at
the backend: input N HTTP-GETs `…/api/devices/dingtian/<deviceId>/input/<N>/on` (and `/off`) on
press/release. The backend ([[fastify]] route `routes/devices.ts`) translates each push into an
internal device event ([[device-input-flow]]); the entry flow then prints a ticket and commands
the relay via UDP. See [[device-input-flow]] for the full path + trust model.
> The input-poll path in the driver (`onInput`) remains as a dev/fallback aid, but **push is the
> real path** — lower latency, and it can be authenticated (the device supports Basic/Digest +
> HTTPS on the push), unlike the open UDP control direction.
### What it pushes vs. doesn't (logging)
- **Inputs (buttons): YES, pushed.** Input changes are HTTP-pushed via `input_link_url` and now
land in the host's signed [[append-only-event-chain]] as `input_received` events (bus →
`EventLog`). That is the audit trail for "a button fired."
- **Relay / barrier opens: NO push, no log.** The device has **no event log of its own** and does
not report when a relay fires — relay control is one-way UDP that the *host* initiates. So
"the barrier opened" is not something to scrape from the device. The host records what it
*commanded* (a future `barrier_open_command` event); a relay open with **no matching signed
host event is itself the anomaly** to alarm on ([[threat-model]]). Do not treat the Dingtian as
a log source — it is a dumb relay+input board; the host is the source of truth.
## Hardening (`harden()`) — and why HTTP auth is not a boundary here
On assign the driver runs `harden()` (the [[device-registry|HardenableDevice]] capability):
1. **`relay_pw`** — set a random relay password so binary relay commands (UDP 60000) need it.
2. **Disable EVERY other channel** — set `p:255` on the string protocol (udp2), rs485, can,
tcp×2, mqtt; keep **only** UDP1 binary, which carries `relay_pw` for both control AND status.
3. **Rotate the `admin`/`admin` web login** — `GET /userset.cgi?<old_u>&<old_p>&<new_u>&<new_p>&`
(response `&0&…&` = success, verified on hardware). The new password is stored back in
config (`webUser`/`webPassword`) so a re-run can rotate again (the device checks the *old*
creds). This step is **best-effort** — a failure logs and does not fail the assign.
> ⚠️ **The string protocol (udp2) is a password-less relay-fire path — the original `harden()`
> left it ENABLED "for status reads", which was a real hole.** The Dingtian string protocol has
> NO password field and can fire relays (`"11"` = relay 1 on, `"21"` = off, `"11*"` = jog).
> **Proven on hardware**: sending `"11"` to UDP 60001 with no credentials opened relay 1,
> completely bypassing `relay_pw`. Fixes: (a) status reads moved to the **authenticated binary
> read** (relay command `0x00`) so the string protocol is no longer needed; (b) `harden()` now
> sets `udp2.p=255` to disable it. **Firmware caveat (V3.6J):** the CONFIG API silently refuses
> to disable udp2 — it accepts the write, reboots, and clamps it back — even though the device's
> **web UI can** disable it. So the udp2 disable is **best-effort + warns** (it is NOT part of the
> blocking verify); if it doesn't stick, `harden()` returns a warning telling the admin to flip
> UDP2 off in the device web UI. Verified: after the web-UI disable, the `"11"` attack gets no
> reply and the relay stays off, while authenticated binary control/status still work.
> 🔑 **Web-login model (bug fixed).** The login set has TWO distinct config keys:
> `webPassword` = the password the admin WANTS (blank → harden generates a random one), and
> `webPasswordCurrent` = the device's EXISTING password (the old cred `userset.cgi` checks;
> defaults to `admin`). The original code conflated them — an admin typing a *desired* password
> made harden send it as the *old* cred, the rotation failed, yet the DB still saved the typed
> value: **the DB claimed a password the device never accepted (login stayed admin/admin).**
> Fix: harden now rotates `current → desired`, **verifies** by re-authenticating with the new
> password, and only then returns `secrets.webPassword`; assign strips the typed inputs and
> persists only the verified value (else a warning, no save). Verified on hardware: device
> rejects `admin/admin` (`&2&`) and accepts the chosen password (`&0&`) after harden.
>
> ⚠️ **The device CGI API is UNAUTHENTICATED.** Verified on hardware: `GET /api/v2/config.cgi`,
> `/`, and even `/userset.cgi` all return **200 with no credentials**. The `admin`/`admin` login
> gates only the interactive **browser UI** — the CGI control plane (read/write full config, fire
> relays, change the password) bypasses it entirely. The `http` config block has **no** setting to
> require Basic/Digest on inbound requests; the only inbound gate is `session_en`, which **bricks
> the config-read API on this firmware** (the factory-reset incident — *do not enable it*). So
> **rotating the login is cosmetic** (stops a casual browser reaching settings); it is **not** a
> boundary. On this flat, no-VLAN network the device control plane is effectively open — the
> **signed event log is the real anti-fraud guarantee**. See [[device-input-flow]].
> ⚠️ **`session_en` must stay OFF.** Enabling the HTTP CGI session check makes the config-read API
> drop connections (ECONNRESET), locking out the API the driver depends on — recoverable only by
> factory reset. `harden()` deliberately never touches it.
## Status — VERIFIED on hardware (DT-R004, sw V3.1.5461A, 10.0.10.172)
- ✅ status read (`0000:1111:4`), relay pulse, input press/release events (active-LOW, idle HIGH).
- ✅ **`input_link_relay` disabled via the driver** → pressing an input reports the event and
**fires NO relay** (`0000` after presses). The [[access-controller-button-flow]] blocker is
**solved**.
- ✅ **Input HTTP-push end to end** — configured the device via `configureInputPush()`, then real
button presses (all 4 inputs) **pushed to the backend** (`/input/N/on` + `/off` per press,
source = the device IP). No polling. Host-in-the-loop entry (`button → backend → ticket →
backend opens relay`) is real.
- ✅ **Web-login rotation** — `userset.cgi` rotates `admin`/`admin` (response `&0&/&`; wrong old
password → `&2&/&`). Confirmed the device validates the old creds. **Also confirmed the CGI API
needs NO auth** (config dump + `userset.cgi` return 200 unauthenticated) → rotation is cosmetic.
- ⬜ Next: wire the actual entry flow (input event → signed event + print ticket → `pulseOpen`).