c08e232339
A NodeMCU v3 (ESP8266) that speaks the Dingtian wire contract (binary UDP 60000 with relay_pw, string UDP 60001, config CGI incl. the setconfig gotcha, userset.cgi, Digest input push) so the booth's existing driver needs no change, plus a heartbeat/command/ watchdog path to an ephemeral cloud stand-in (poc/cloud-standin.mjs). Verified at park-lab: the booth's assign flow configured it like real hardware and a button press reached the booth (401→Digest→200) and the cloud with the booth's status. Watchdog probes /health and power-cycles the PC via a spare relay with backoff. IO behind one interface for the ESP32/ Dingtian port. wiki: relay-proxy-firmware page; esp32-flashability-test runbook (esptool lock test); dingtian-relay "can we flash our own firmware" (vendor locks the standard SKU); site-device-installation: booth ufw must allow device-net → 3000 (push targets PORT, not Caddy's 80); open-questions: cloud takeover vs signed ledger (parked). .gitignore: firmware venv/.pio/secrets.h.
72 lines
3.6 KiB
Markdown
72 lines
3.6 KiB
Markdown
# relay-proxy — Dingtian emulator + cloud proxy/watchdog (PoC)
|
|
|
|
A NodeMCU v3 (ESP8266) that **is a Dingtian DT-R004 to the booth server** and, on top, a
|
|
**proxy and watchdog toward a cloud service**. The booth's existing `dingtian` driver talks to
|
|
it unchanged. It is the seed of the custom firmware for the real Dingtian board (ESP32); the IO
|
|
layer is the only board-specific file.
|
|
|
|
Why: park-2's booth PC died twice unnoticed. The device that already owns the barrier relay and
|
|
the button inputs becomes the resilient core: it reports to the cloud independently of the PC,
|
|
can power-cycle the PC, and keeps accepting commands from the cloud when the PC is dead.
|
|
See `wiki/entities/dingtian-relay.md` and `wiki/decisions/cloud-service-saas.md`.
|
|
|
|
## What it emulates (the booth sees a DT-R004)
|
|
|
|
| Surface | Behaviour |
|
|
| --- | --- |
|
|
| UDP 60000 binary | `FF AA s cmd pwLo pwHi …`: `00` status, `01` write (mask,set), `03` jog. Reply `FF AA s cmd relayByte inputByte`. Wrong `relay_pw` → dropped silently. |
|
|
| UDP 60001 string | `00`, `1N`, `2N`, `1N*`. Password-less. Enabled at factory; `harden()` turns it off (`udp2.p=255`). |
|
|
| `GET /api/v2/config.cgi` | The config JSON (relay_connect, input_link_relay, input_link_url). |
|
|
| `POST /api/v2/config_set.cgi` | Applies + persists (LittleFS). Requires `"command":"setconfig"` like the real device. |
|
|
| `GET /userset.cgi?u&old&u&new&` | Web-login rotation, `&0&` ok / `&2&` wrong old password. |
|
|
| Input push | On input change, Digest-authenticated GET to the booth's `on_path`/`off_path`. |
|
|
| `input_link_relay` | Factory ON (input auto-fires its relay) until the booth's precondition fix clears it. |
|
|
|
|
Extra, PoC-only: `GET /` status text, `POST /poc/factory_reset`.
|
|
|
|
## Proxy / watchdog (toward `CLOUD_URL`)
|
|
|
|
- Heartbeat every 10 s: IP, booth health, relay/input state, config flags.
|
|
- Every input change is mirrored to the cloud (`/event`) with the booth push result.
|
|
- Command poll every 2 s: `{"pulse":ch,"ms":500}`, `{"watchdog":false}`, `{"reboot_pc":true}`.
|
|
- Watchdog: probes `BOOTH_HEALTH_URL` every 5 s; after 6 failures in a row it pulses relay 2
|
|
for 3 s (meant for an NC contact in series with the PC's mains, with BIOS AC Recovery = On),
|
|
then backs off 10 min. The cloud can disable it.
|
|
|
|
## Pins (NodeMCU v3) — no wiring needed to start
|
|
|
|
| Function | Pin |
|
|
| --- | --- |
|
|
| Relay 1 (barrier) | D1 / GPIO5, mirrored on the on-board LED |
|
|
| Relay 2 (PC power) | D2 / GPIO4 |
|
|
| Relay 3, 4 | D5 / GPIO14, D6 / GPIO12 |
|
|
| Input 1 (button) | the on-board **FLASH** button (GPIO0), active LOW |
|
|
| Input 2 | D7 / GPIO13, short to GND |
|
|
|
|
## Build / flash
|
|
|
|
```
|
|
cd firmware/relay-proxy
|
|
copy include\secrets.h.example include\secrets.h # fill in; gitignored
|
|
..\.venv\Scripts\pio run -t upload
|
|
..\.venv\Scripts\pio device monitor
|
|
```
|
|
|
|
Cloud stand-in (throwaway): `node poc/cloud-standin.mjs` on a host the device can reach.
|
|
|
|
## Register it in the booth
|
|
|
|
Devices → add **Dingtian relay controller**: host = the NodeMCU's IP (give it a DHCP
|
|
reservation or set `STATIC_IP`; the booth only accepts pushes from the registered IP),
|
|
channels 4, binary port 60000, string port 60001, HTTP port 80. On save the booth runs the
|
|
normal flow: precondition fix (clears `input_link_relay`), `harden()` (random `relay_pw`,
|
|
disables udp2, rotates the web login), and `configureInputPush()` (Digest creds + URLs).
|
|
The serial log shows each step land.
|
|
|
|
## Limits of the PoC
|
|
|
|
- Wi-Fi only; the real target has Ethernet.
|
|
- HTTP calls block the loop briefly (~100 ms); fine for a demo, not for production.
|
|
- The config JSON mirrors the keys the booth driver uses, not the full device schema.
|
|
- Plain HTTP to the cloud stand-in; the real cloud link needs TLS.
|