Files
parking_solution/wiki/entities/zkteco-cmp200-barrier.md
julian 726dd9803a wiki: passage confirmation — zone PoC, flow and relay rules, trials, hardening list
- passage-confirmation: unexplained passages as the audit witness and the
  phase-1 order (2026-11-19), first recordings, and the decisions of
  2026-11-22: the zone flow (last crossing counts, no decision while the zone
  is busy, an uncrossed open is abandoned) and the read-then-fire relay rules.
- zone-anpr-poc: the prototype on park-lab, its builds, the live R2 trials and
  the turn-back judged as passed; park-lab as the worst-case site.
- zone-anpr-plate-trials: plate reading measured (inverting does not help; the
  still is the main reader; the plate reads only on a short stretch of the
  approach), the day and wet-night trials, and the two fixes that followed.
- zone-anpr-poc-review: the code review of 2026-11-21 with a status table of
  what the later builds fixed.
- vision-hardening: the work list the user deferred to another session.
- zkteco-cmp200-barrier, append-only-event-chain, reconciliation,
  open-questions, overview, index, log: cross-references and updates.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01RZgP5oZdzvo92Eouc9eRv5
2026-11-22 18:24:48 +01:00

105 lines
6.7 KiB
Markdown
Raw Permalink Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
---
type: entity
tags: [parking, hardware, barrier, relay, wiring]
sources: []
updated: 2026-11-22
---
# ZKTeco CMP200 Barrier Gate
The boom barrier on hand. Its mainboard (silkscreen on our unit: `TT-DZ-200504E-A1`) drives an
**AC capacitor-start motor** through on-board relays; limits are Hall switches. Mains 110/220 V AC,
100 W rated. Not to be confused with the [[zkteco-controller]] (access panel, rejected).
Web research 2026-11-14. Sources: ZKTeco CMP200 user manual v1.0 (2019) and v1.2 (March 2022),
wiring diagrams read from the PDFs:
<https://bsai.com.mx/cdn/shop/files/ZKTECO-CMP200-Barrera--Vehicular-Manual-de-Operacion-Ingles.pdf>,
<https://manuals.plus/zkteco/cmp200-automatic-barrier-gate-manual.pdf>.
No public document names the `TT-DZ-200504E-A1` board, but a photo of our unit (user, 2026-11-14)
matches the **v1.2** layout: `MOTOR UP/COM/DOWN`, `COM/RED/GREEN`, `L/N/E`, `O.LM OUT`, `C.LM OUT`,
`STOP/DOWN/UP/STUDY` keys, status LEDs, and a 2x8 socket marked `RS485`. MCU is an **STC 15W408AS**
(8051 family); on-board transformer 220 V to 12 V / 600 mA; PCB date code 230602. The labels of
the low-voltage terminals sit under the plug-in connectors and were not visible — pull the plugs
to confirm them against the table.
## Terminal map (manual)
| Terminal | Function | Signal |
| --- | --- | --- |
| `G` / `STOP` / `DOWN` / `UP` | "Line-controlled interface": wired open/close/stop | dry contact, short to `G` |
| `G` / `DET` | vehicle (loop) detector | dry contact to `G` |
| `G` / `PHO` | infrared / "crash proof" sensor | dry contact to `G` |
| `CAR` (v1.2 only) | "count input" | dry contact to `G`; behaviour undocumented |
| `RS485 B / A / G` (v1.2 only) | "communication module" | see below |
| `+12V` / `G`, `+5V` / `G` | auxiliary supply | 12 V total under 100 mA |
| `O.LM OUT`, `C.LM OUT` | open-limit and close-limit relay outputs | volt-free NO/COM/NC each |
| `G` / `C.LM` / `O.LM` | external limit junction | — |
| `MOTOR UP/COM/DOWN`, `LAMP COM/RED/GREEN`, `L/N/E` | motor, AC traffic lamp, mains | **mains voltage** |
The v1.0 board has no RS485 and no `CAR`. The 4-pin `REMOTE` header takes the 433 MHz receiver.
## Behaviour the manual states
- `UP` during a fall reverses to rising at once. `DOWN` during a rise is ignored. `STOP` halts.
- `PHO` shorted during a fall: reverse to open, then **stay open**.
- `DET` shorted during a fall: reverse to open, then **close automatically** when released. `DET`
shorted while open or rising: the boom **falls by itself** once the detector clears. So `DET` is
both anti-smash and auto-close-after-passage, done in the barrier's own firmware.
- Timeout protection stops the motor if a travel exceeds the rise/fall time.
- No menu, no parameters, no auto-close timer are documented. Power-loss behaviour is not stated
beyond "manual release motor" — the boom does not lift by itself.
## Driving it from the [[dingtian-relay]]
**Relay contact, not RS485.** ZKTeco's own integration drawings (LPR camera, inBio260) wire a relay
`COM → G` and `NO → UP`. That is exactly our `pulseOpen`: one Dingtian relay, `COM` to `G`, `NO` to
`UP`, jogged. It expresses intent only and never times a close ([[barrier-not-a-door]]).
- **Closing** normally comes from the loop/radar on `DET`, in barrier firmware. Without a vehicle
tripping `DET` the boom stays up — the abandoned-entry free pass of [[passage-confirmation]].
- **Host close (only under [[passage-confirmation]]'s conditions):** a second relay on `DOWN`,
interlocked in series so it is dead while the open relay is active — relay 1 `COM → G`,
`NO → UP`, `NC →` relay 2 `COM`; relay 2 `NO → DOWN`. Never one relay with `NC → DOWN` (a
permanent close command; closes on controller power loss). Per the manual a `DET` or `PHO`
contact reverses a falling boom, so the close is not blind **if a detector is fitted** — to be
proven on the unit (test plan steps 2–3 there) before any use.
- **Dingtian "Mutually Exclusive" is not this interlock (user, 2026-11-21).** The board can pair two
relays so that switching A on turns B off ("to protect the motor"). That makes the **last**
command win: a close on relay 2 would cut a held open on relay 1. The series wiring above makes
**open** win (relay 2 is dead while relay 1 is on), which is what [[barrier-not-a-door]] needs.
The board setting may be enabled as well, but it does not replace the wiring, nor the `DET`/`PHO`
proof on the unit.
- **Status back to the host:** `O.LM OUT` and `C.LM OUT` are volt-free contacts, so they can go
straight onto two Dingtian inputs (contact to GND, like the button). That gives the host a real
"boom reached open / closed" signal for [[device-status-monitoring]] and for the anomaly "boom
opened with no signed host command" ([[threat-model]]).
- **The close does not need that signal (user, 2026-11-22).** R2 fires on an abandoned open
without looking at the boom, and a close on a closed boom is expected to do nothing (not yet
tried on the unit). The relay rules are on [[passage-confirmation]], "Relay rules".
- **Sharing a detector:** a radar/loop with one dry contact cannot feed both `DET` and a Dingtian
input directly (two different supplies on one contact). Use a detector with two relay outputs
or an interposing relay.
- Keep the low-voltage terminals apart from the mains block on the same board edge.
**RS485 — not a usable path today.**
1. The barrier's RS485 protocol is **undocumented**. The manual labels the terminals and a plug-in
"RS485 communication module" header and says nothing else: no baud, no address, no frames. On
our board the **socket is empty — no module fitted**, so the `B/A/G` terminals have no
transceiver behind them and are dead as shipped. Manuals for similar Chinese `DZ`-family boards show
a 4-byte, 9600 bps, XOR-checksum frame, but nothing ties that to this board — unverified.
2. The Dingtian's RS485 port is an **inbound control channel** (Modbus-RTU / Dingtian string: a
master commands the Dingtian). Stock firmware is not documented as an RS485 master or an
Ethernet-to-RS485 bridge, and our `harden()` disables that channel. `(unsourced beyond the
programming manual's protocol list — check the vendor manual before relying on either way)`
3. A serial "open" command would also be an unauthenticated open path on a wire in the lane
cabinet — worse than the password-carrying relay frame we already have.
## Open
- Pull the low-voltage plugs and read the silkscreen under them (`G DET CAR +12V G +5V G C.LM O.LM`
and `G STOP DOWN UP / B A G / G PHO` expected).
- What `CAR` does (probably queues several opens for a convoy) — test on the bench.
- Fail-state: on power loss the boom holds position, so "exit fails open" ([[fail-state-safety]])
needs the manual release or a UPS, not this board.