6eb65361a8
- concepts/park-2-event-loop-stall: /api/sessions/active ~2 s synchronous (quote() per open unpaid transient x664, unindexed ledger scans) froze the loop; Node runs expired timers before queued UDP replies, so healthy Dingtian pulses reported "timeout" and signed entries lost their snapshot/session row. Standing decision: bounded request cost whatever the operator data. - Dingtian: custom firmware retired (2026-10-23), runbook shelved, vendor pinout in raw/, relay-proxy PoC marked retired; edge-controller hardware memo (open).
84 lines
5.1 KiB
Markdown
84 lines
5.1 KiB
Markdown
---
|
|
type: entity
|
|
tags: [parking, hardware, firmware, esp8266, dingtian, cloud, watchdog, poc]
|
|
sources: []
|
|
updated: 2026-10-23
|
|
status: retired
|
|
---
|
|
|
|
# relay-proxy — Dingtian emulator + cloud proxy/watchdog firmware (PoC, retired)
|
|
|
|
> **Retired 2026-10-23.** The Dingtian-firmware path this PoC seeded is dropped (user decision:
|
|
> focus on mini PCs for booth resilience). The code stays in `firmware/relay-proxy/` as a working
|
|
> Dingtian protocol emulator — still useful as a **bench stand-in when no real relay board is on
|
|
> hand** — and the watchdog/heartbeat ideas carry over to whatever runs beside the booth PC.
|
|
|
|
Code: `firmware/relay-proxy/` (PlatformIO, Arduino framework; NodeMCU v3 / ESP8266 now, ESP32
|
|
env planned for the real [[dingtian-relay]]). Throwaway cloud stand-in: `poc/cloud-standin.mjs`.
|
|
|
|
## Why
|
|
|
|
park-2's booth PC died twice unnoticed ([[appliance-provisioning]] incident 2026-10-17). The
|
|
idea (2026-10-22): the device that already owns the barrier relay and the button inputs becomes
|
|
the resilient core — it reports to a multi-tenant cloud independently of the PC, can
|
|
power-cycle the PC, and keeps taking relay commands from the cloud when the PC is dead. Custom
|
|
firmware on the Dingtian is the natural home ([[esp32-flashability-test]] gates that); the
|
|
NodeMCU is the stand-in while no flashable Dingtian is on hand. Ledger implications of a cloud
|
|
takeover mode are **deliberately parked** (see [[open-questions]]).
|
|
|
|
## What it is to the booth: a DT-R004
|
|
|
|
The firmware speaks the Dingtian wire contract so the booth's `dingtian` driver is unchanged:
|
|
binary UDP 60000 (`00` status / `01` write / `03` jog, `relay_pw` checked, wrong password
|
|
dropped silently), string UDP 60001 (password-less; disabled when `udp2.p=255`),
|
|
`GET /api/v2/config.cgi`, `POST /api/v2/config_set.cgi` (requires `"command":"setconfig"`,
|
|
exactly like the hardware gotcha), `GET /userset.cgi` (`&0&` / `&2&`), and Digest-authenticated
|
|
input push to `on_path`/`off_path`. Config persists in LittleFS; factory state has
|
|
`input_link_relay` ON so the booth's precondition fix is exercised.
|
|
|
|
**Verified 2026-10-22 from the dev PC** (board at 10.0.10.101 on the ArtServis Wi-Fi, which lands
|
|
on the park-lab device net): status reply `ff aa s 00 <relay> <input>`, jog/write/release, string
|
|
`00`→`0000:1111:4`, setconfig-only writes, login rotation codes, cloud → relay pulse.
|
|
|
|
## What it adds: proxy + watchdog
|
|
|
|
Heartbeat to the cloud every 10 s (IP, booth health, relay/input state, config flags); every input
|
|
change mirrored to the cloud regardless of booth push config; cloud command poll (`pulse`,
|
|
`watchdog`, `reboot_pc`); watchdog probes the booth `/health` every 5 s and after 6 misses pulses
|
|
relay 2 for 3 s (NC contact in series with the PC mains + BIOS AC Recovery=On = reboot), 10-min
|
|
backoff, cloud can disable. This is the detect+remediate layer park-2 lacked.
|
|
|
|
## Booth integration — VERIFIED end to end (2026-10-22, park-lab)
|
|
|
|
After `ufw allow from 10.0.10.0/24 to any port 80,3000 proto tcp` on park-lab (see
|
|
[[site-device-installation]] "Booth host firewall"): the admin added the board in park-lab's setup
|
|
as a Dingtian controller (host 10.0.10.101). The booth's assign flow landed on the board exactly as
|
|
on hardware — `input_link_relay` cleared, random `relay_pw`, every channel but UDP1 set to 255
|
|
(udp2 really off: `00` on 60001 times out), web login rotated (`admin/admin` → `&2&`), Digest push
|
|
to `10.0.10.198:3000/api/devices/dingtian/<id>/input/N/{on,off}`. A FLASH-button press then
|
|
produced: board → booth `401` challenge → Digest retry → `200`, booth log
|
|
`[dingtian:<id>] input 1 on (push)` + `off`, and the cloud stand-in received `input_on` /
|
|
`input_off` with `booth_status=200` — the same event seen by booth and cloud independently. The
|
|
watchdog flipped to `booth UP` the moment port 80 opened.
|
|
|
|
## Open
|
|
|
|
- The booth's ufw rule set is root-only and undocumented — belongs in [[appliance-provisioning]].
|
|
- The booth accepts pushes only from the registered host IP → the board needs a DHCP reservation
|
|
or `STATIC_IP`.
|
|
- ESP8266 limits (Wi-Fi only, ~40 KB heap, blocking HTTP) are PoC-only; the target is the ESP32
|
|
on the Dingtian with Ethernet. Camera traffic is never proxied by the microcontroller.
|
|
- **Superseded as a hardware target (2026-10-22):** the takeover only works if the controller also
|
|
fronts the readers and the printer, which needs a Linux box with a Node runtime; the microcontroller
|
|
cannot. Hardware options and the watchdog policy (take over at one missed probe, power-cycle only when
|
|
the PC is dead at every layer) are on [[edge-controller-hardware]]. The emulation and watchdog logic
|
|
here carry over to the port.
|
|
|
|
## Bench note: NodeMCU v3 clone CH340 vs WCH driver
|
|
|
|
The board's USB-serial reports `USB\VID_1A86&PID_7523&REV_0254` and WCH drivers 3.9/4.0 refuse it
|
|
("A device attached to the system is not functioning" on every open). Fix applied 2026-10-22:
|
|
WCH driver **3.4.2014.08** (SparkFun mirror, WHQL catalog + Qinheng-signed setup verified),
|
|
staged with `pnputil /add-driver`, newer package exported to scratch then deleted from the store
|
|
so the port rebinds. Windows Update may push 4.0 back; repeat if the port fails again.
|