Files
parking_solution/wiki/entities/gee-qr-er80.md
T
julian 1efa77bf56 devices: pool-of-spaces model — drop lane, per-relay direction
A parking lot is one pool of spaces with a flexible set of entry/exit
points — no "lane". Direction is a property of each RELAY inside an access
controller; readers/cameras bind to a controller relay and inherit it.

Schema:
- drop `lane` from ledger_events, device_events, sessions
- rename lane_devices -> devices (no lane/direction columns)
- access config.relays=[{relay,direction,button?}]; reader/camera
  config.controllerId+relay binding
- fresh 0000_baseline migration (history reset; dev data was throwaway)

Signed ledger:
- remove `lane` from canonicalize(); bump signer keyId sw-hmac-v1 -> v2
  (v1 events won't verify under v2 — intentional, gated per-event by keyId)

Server:
- new device-resolve.ts (replaces lane-map.ts): relayForButton,
  relayForDevice, firstRelayByDirection, devicesByDirection
- entry-flow: button terminal -> its relay; exit/permit: reader's bound
  relay; dispatcher resolves the bound relay + inherited direction
- camera snapshots fire by direction site-wide, async, never block open
- DeviceConfig widened to nested JSON for relays[]

Web:
- wizard: no lane selector; add controllers (relay map + entry-button
  terminal) first, then bind readers/cameras/printers to a controller relay

Wiki: new entry-exit-points.md (replaces lane-direction); reworked
entry-exit-readers, parking-session, first-run-setup, device-registry,
append-only-event-chain, device-events; removed stale lane/LaneMap mentions.
2026-06-16 20:29:38 +02:00

7.3 KiB
Raw Blame History

type, tags, sources, updated, status
type tags sources updated status
entity
parking
hardware
readers
qr
gee-qr-er80
2026-06-16 open

GEE-QR-ER80 (QR access reader)

The project's QR-code reader (GEE NFC LIMITED). A static optical scanner for QR / DataMatrix / 1D barcode, optional ID/IC card. This is the ticket-encoding scanner the design called for — read at the pay station and exit lane — and a path for QR permit credentials. On hand: variant -Q-W (QR scanner; Wiegand/RS-232/RS-485). (See gee-qr-er80 / raw/.)

What it is (and isn't)

  • Optical, not RFID-prox. Earlier we assumed "ER80-EM" = a 125 kHz EM4100 card reader — the datasheet corrects that: it's a QR/barcode scanner. The -EM in the original label was a mis-id; the real model is GEE-QR-ER80. Optional D/C variants add ID/IC card, but the unit on hand is QR-only (-Q).
  • Multi-interface (Wiegand 26/34, RS-232, RS-485, USB, TCP/IP); the -W variant exposes Wiegand + RS-232/RS-485.

How it integrates — HTTP-GET push, server replies the verdict (confirmed via SDK)

The protocol is settled by the qrcode-sdk (not serial as first guessed). The reader is configured (Windows tool QRCode_v1_6_5.exe) with a server IP/port and a "server language" (only picks the URL path, e.g. /qa/mcardsea.php). On each scan it HTTP-GETs the host:

GET /qa/mcardsea.php?cardid=<QR>&mjihao=<devId>&cjihao=<devSN>&status=<2 chars>&time=<utc>

cardid = scanned data; status low digit = direction (1=in / 0=out). The host replies JSON {data:[{cardid,cjihao,mjihao,status,time,output}],code:0} where reply status 1=valid (beep 2×) / 0=invalid (beep 1×), output 0=Access/1=WG26/2=WG34, time syncs the clock.

This is host-in-the-loop and SYNCHRONOUS: the GET is the access query and our reply is the decision — it drives the reader's beep + output. So unlike a fire-and-forget reader, the endpoint must decide (valid/invalid, direction from status) and reply, then also emit a DeviceReadEvent on the read bus for the entry/exit/permit flows (parking-session, permit) to open the barrier. (device-input-flow is the analogous push pattern; this one also returns a verdict.)

This explains the "no beep": feedback comes from the server's JSON reply, not locally. A non-JSON / missing reply ⇒ no beep even though the scan worked. So "no beep" ≠ "didn't scan."

  • Pushes over plain HTTP to our 10.0.10.x host (on the device subnet); no serial wiring, no Wiegand-decode hardware. Suits the host-in-the-loop model; autonomy is moot anyway (dingtian-relay has no onboard ACL).
  • Linux-supported, 4–15 VDC, default IP 192.168.1.99 — fits the disk-os-hardening.

Resolved (2026-06-16)

  • Protocol = HTTP GET poll + JSON verdict (above). The earlier "serial/Wiegand, find the baud" open questions are moot — it's HTTP. Wiegand is the reader's output line on a valid read (the reply output field), not the host transport.

As-built (2026-06-16)

  • Endpoint GET/POST /qa/mcardsea.php (apps/server/src/routes/qr-reader.ts, public — the reader has no auth, sits on the device subnet). Parses cardid/mjihao/cjihao/status/time, runs the scan through the read dispatcher (permit match → permit flow; else transient exit), and replies the SDK verdict: status 1=valid(beep 2×)/0=invalid(beep 1×), output 0, time.
  • The read flows were refactored to return a ReadOutcome { accepted, direction, reason } so the endpoint's reply reflects the real accept/reject (the dispatcher decides AND opens the barrier via the flows). A fire-and-forget reader ignores the outcome.
  • Reader identity: the endpoint matches the device serial (cjihao) against each reader's config.serial to find its devices row; the dispatcher then resolves the relay that row is bound to (config.controllerId + relay) and opens it. See entry-exit-points.
  • Verified via inject: valid permit QR → status:1 + open; re-scan → permit exit (still valid); unknown QR → status:0; reader on a barrier-less lane → status:0.

Verified on hardware (2026-06-16)

Captured a real scan (vendor-emulator logger on :3000). The reader does scan, send, and beep — the earlier "no beep" was simply that no server was answering on :3000 with valid JSON. Real GET:

GET /qa/mcardsea.jsp?cardid=52020056&mjihao=1&cjihao=H05M2AFA&status=11&time=1781634494
from 10.0.10.7   (referer: http://www.fondvision.com — the OEM is Fondvision)
  • PATH carries the configured "server language" EXTENSION: this unit is set to JSP, so it GETs /qa/mcardsea.jsp — NOT .php. Our endpoint was registered at .php only → it would have 404'd the real reader. Fixed: the route now registers php/jsp/asp/aspx/cgi.
  • cjihao = H05M2AFA is the device serial — the value our endpoint matches against the reader's config.serial. So assign the reader with config.serial = "H05M2AFA" and bind it to a controller relay.
  • mjihao = 1 (device id). cardid = the scanned barcode (52020056). status=11.
  • The reader beeped on the vendor reply with status:0 — so it acts on the reply; 0 = invalid/1-beep as documented. A matching permit/session will return status:1 → 2-beep accept.

Assignment (as-built 2026-06-16)

A dedicated gee-qr-reader driver (device-registry, reader category) models the push reader: its one config field is serial (the cjihao the device reports). The admin assigns it in the first-run-setup like any device (normal UUID row id), enters the serial, and binds it to a controller relay. The QR endpoint resolves the reader by matching config.serial to the scan's cjihao — not by row id — so no DB hand-editing. Set the reader's server IP/port to this host in the vendor tool; assign + enter its serial + bind it here.

  • Verified via inject: assign gee-qr-reader {serial:"H05M2AFA"} bound to an access relay → a .jsp scan with that serial + a matching permit QR → status:1 (2-beep accept) + open; re-scan → permit exit; unknown card → status:0; unassigned serial → status:0 (no relay, graceful).
  • Note tcpip-reader is the WRONG model for this device (host-connects-out, a stub) — use gee-qr-reader.

Open / next

  • Re-test on hardware against the real app (now .jsp-aware + serial-resolved): scan → expect a status:1 2-beep when the QR matches a permit/open session.
  • output is replied as 0 (Access). Confirm on hardware whether the reader needs 1/2 (WG26/34) to drive its access line, vs. 0.

⚠️ Reply MUST set Connection: close (verified on hardware)

The reader sends Connection: keep-alive but only acts on the verdict (beep/output) once the TCP socket CLOSES. Fastify's default keeps the connection alive → the reader waits out a ~10 s keep-alive timeout before beeping, even though the server replied in ~15 ms. Every vendor demo replies Connection: close and shuts the socket. Fix: the endpoint sets reply.header("connection","close"). Symptom if regressed: correct accept/reject but a ~10 s lag before the beep. (The request arrives fast; the delay is entirely the reader waiting for close.)