4d1d245680
Two DT-008 units read disjoint card sets (park-buzi 125 kHz, lab unit 13.56 MHz only) although the box leaflet claims EM-ID + M1 + ISO 14443A/B + 15693 in one unit; recorded as unresolved with the EM4100 test that settles it (open question #18). Phone taps give a random 08… UID per tap, so phones are never RF credentials; 6H keeps the first three UID bytes reversed. Runbook §2 gains the tool's Setting-tab layout, a capability-identification checklist and the per-technology parameter table. reader-sink.py is a stdlib bench sink answering the push with the SDK verdict and Connection: close. Claude-Session: https://claude.ai/code/session_01FWncR69HgGPuei1dLrW3cU
1.7 KiB
1.7 KiB
type, tags, sources, updated
| type | tags | sources | updated | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| source |
|
|
2026-09-17 |
Source: DT-008 paper manual from the box ("QR Code Reader Technical Parameter")
Phone-scanned (OCR) from the leaflet packed with the fresh lab unit HC002721, 2026-09-17. Verbatim
as OCR'd (typos are the OCR's):
QR Code Reader Technical Parameter
Voltage Support: DC 5V-16V
Current: ≤0.75W
Decoding support: QR code, one dimensional code
Reading range: ID 1~10CM, IC 1~5CM
Reading card type: EM-ID, M1, 15693, 125KHZ \ ISO14443A \ ISO14443B \ ISO15693
Application environment: -10°C ~ 60°C
Humidity: 10% ~ 90%
Interface: Wiegand26, 34, RS485, RS232, [USB?]
What it claims that matters
- All card technologies in one unit: EM-ID (125 kHz), M1 = Mifare Classic (ISO 14443A), ISO 14443B, ISO 15693. Range differs by technology: ID 1–10 cm, IC 1–5 cm.
- RS232 is listed — the earlier wiki position "NOT RS-232, that was a fictional-datasheet claim" came from the mis-identified GEE PDF; the box leaflet does list it. Irrelevant to us (HTTP push), but do not treat the interface list as evidence of a mis-id any more.
- Power 5–16 V here vs 9–16 V / 800 mA on the product page (dingtian-dt008).
What it does NOT settle
The lab unit does not read the park-buzi card set although the leaflet says it reads EM-ID — see dingtian-dt008-reader §"Two RF variants". Either the leaflet is generic for the line and units ship per variant, or the lab unit's 125 kHz front end is dead/disabled, or the park-buzi cards are a non-EM 125 kHz format (HID Prox / Indala / AWID) that only the older batch decodes.