Turborepo (pnpm workspaces) with all dependencies pinned to latest mutually-compatible versions: turbo 2.9, TypeScript 6, Fastify 5, React 19, Vite 8, better-sqlite3 12 + Drizzle ORM 0.45. Layout: - apps/server Fastify backend (local JWT auth + role guard, /health) - apps/web React 19 + Vite 8 operator SPA - packages/db Drizzle schema on SQLite/WAL; append-only events + users - packages/devices reader/printer/relay adapter interfaces (intent-only relay) - packages/shared shared domain types Architecture constraints from the design wiki are encoded in the scaffold: append-only hash-chained + signed event log, device-agnostic adapters, "a barrier is not a door" (relay expresses intent only), fully-local offline-first auth. wiki/ is an LLM-maintained Obsidian knowledge base (28 pages) ingested from the architecture & design notes, with its own maintenance schema. Verified: pnpm install, full turbo build (5/5), server boots and serves /health, drizzle-kit generates the initial migration.
881 B
881 B
type, tags, sources, updated
| type | tags | sources | updated | ||||
|---|---|---|---|---|---|---|---|
| concept |
|
|
2026-06-14 |
Fail-State & Safety (custom controller)
For the esp32-custom-controller, fail-state behaviour is to be treated as seriously as the crypto. (See parking-system-architecture §7.)
- Define behaviour on power/network/host loss: entry fails closed, exit fails open — never trap a vehicle (often a legal egress requirement).
- Hardware manual override (key switch/button) that opens the barrier with the ESP32 dead.
- Watchdog with a defined safe default.
- The barrier operator still owns physical safety — the ESP32 only signals intent (barrier-not-a-door).
The general "fail-open on exit" principle is also an open-questions (#2) for the system as a whole, not just the custom controller.