Site device installation — know it BEFORE you are standing in the booth
A field runbook: for every device we deploy, its factory address and credentials, the tool you need, what the app configures by itself at assign time versus what must be done by hand on the device, and the traps already paid for on park-buzi and the lab. The appliance-provisioning runbook covers the booth PC (OS, disk, Docker, Periphery); this page covers everything plugged into it. Written 2026-09-09 after an evening lost to a printer whose factory address nobody had written down (k200l-printer).
Rule of thumb that explains most of this page: every field device ships on its own private subnet with DHCP off, and none of them announce themselves. You bring a laptop that can take a second static address, you put it on the device's factory subnet, you move the device to the site plan, and only then does anything else see it.
Before leaving the office
Bring
- A laptop with an Ethernet port and the right to add a second static IPv4 address to it
(Windows: adapter → IPv4 → Advanced → add). Under WSL, remember the source-address bug
(wsl-dev-networking): after adding a temporary address,
pingmay work while HTTP times out. - The Dingtian reader tool
QRCode_v1_6_5.exe(Windows) orscripts/dingtian_qr.py(Python 3, runs on the booth itself — see dingtian-qr-linux-tool) for a DT-008's IP, server target, output type, prefixes and card format. Symbologies are set in neither (no known path). A browser is enough for everything else. - Patch cables, a USB A–B cable (printers), the site's address plan (below) filled in, the app admin password, and a fresh Komodo onboarding key if the booth PC is new (appliance-provisioning §7a).
- The serials if already known: DT-008
cjihao(on the reader's label / in the tool), camera MAC/serial, printer model (label on the bottom — the K200L's own web UI calls it "POS-80").
Address plan — the device VLAN (network-isolation) is 10.0.10.0/24 on both sites so far,
every device static, DHCP off everywhere. The convention from park-buzi / park-lab:
| Address | Device | Factory address it came from |
|---|---|---|
| 10.0.10.1 | VLAN gateway (switch/router) | — |
| 10.0.10.5 | dingtian-relay board (barriers + inputs) | 192.168.1.100 |
| 10.0.10.7 / .8 | dingtian-dt008-reader entry / exit (unique IP each) | 192.168.1.99 |
| 10.0.10.9 | entry-dispenser printer (park-buzi: Cashino KP-300H) | not recorded — fill in |
| 10.0.10.10 | booth-receipt printer (park-buzi: rongta-printer) | not recorded — fill in |
| 10.0.10.11 / .7 (lab) | k200l-printer | 192.168.123.100 |
| 10.0.10.12 / .13 | lpr-camera entry / exit (Hikvision DS-2CD1047G3H-LIU) | 192.168.1.64 (Hikvision default; needs activation) |
| 10.0.10.203 | the booth PC on the device VLAN (the backendIp every device pushes to) |
— |
Fill the real numbers into the site record before you drive; the wizard asks for the booth's push address once and writes it into the Dingtian and the cameras.
1. Dingtian relay board (DT-R004 family) — barriers, button, radar
Factory: IP 192.168.1.100, web UI on port 80, login admin / admin, UDP 60000 (binary) /
60001 (string), multicast discovery 224.0.2.11:60000. See dingtian-relay.
By hand, on the device (browser at its factory address): set the site IP / mask / gateway in the Network page and reboot. That is the only thing you must do by hand. Optional but recommended: in the web UI disable the UDP2 "string" protocol (a password-less relay-fire path); the app's harden step tries to disable it and warns if the device refused — then do it here.
Wiring: button on I1 (NO contact to GND, idles HIGH, pulls LOW on press); radar dry contact on I2; barrier operator's open input on relay 1 (entry) and relay 2 (exit); a spare relay for the entry button lamp (button-light-indicator). One board can carry both barriers; two distant barriers = two boards (entry-exit-points).
What the wizard does on assign (first-run-setup, device-input-flow): finds the board by
multicast ("Scan for controllers" — laptop/booth must share the L2 segment), checks and clears
input_link_relay (factory default auto-fires a relay from its input — the app must decide, not the
board), sets a random relay password (UDP binary), disables every other control channel, rotates
the web login, and writes the input push URL + per-device Digest credentials so button/radar
edges reach the booth PC. You enter the relay map (which relay is entry/exit/both) and the inputs
(button → its relay; radar → presence, activeLow if it idles opposite the button —
hikvision-radar).
Traps
- The HTTP CGI API is unauthenticated on this firmware;
admin/admingates only the web page. Never enablesession_en— it bricks the config API and only a factory reset recovers. The VLAN is the boundary, not the login (dingtian-relay §Hardening). - A relay password mismatch shows as "offline despite ping": the status query is answered only with the right password. Re-assign / re-enter the relay password in the device form.
- "Relay test" in Setup pulses real hardware and signs a ledger event — use it to prove wiring, once per relay.
2. Dingtian DT-008 QR + RFID readers
Factory: IP 192.168.1.99; no web UI — everything is set over the network with
QRCode_v1_6_5.exe (Windows) or scripts/dingtian_qr.py (any OS; same UDP protocol,
reversed 2026-10 — dingtian-qr-linux-tool). See dingtian-dt008-reader.
From the wizard (app builds after 2026-10-08): add a reader → Skano LAN-in / Scan the
LAN lists every DT-008 on the device VLAN with its mode and current server; Use fills
serial + IP; Test says whether it is in HTTP mode and whether the serial matches; Save
switches it to HTTP and points its server at this booth (items 2 and 6 below, done for you).
Items 1, 3, 4, 5 are still manual (IP via set-network, prefixes/card format via set, both in
scripts/dingtian_qr.py; symbologies only in the exe). Needs the reader's IP in the form — with
it blank the save warns and configures nothing.
By hand (vendor tool, or scripts/dingtian_qr.py from the booth), per reader:
- Unique device IP (
.7entry,.8exit). Two readers on one IP was the 2026-06-18 "wrong barrier" incident — scans land on the wrong device row. - Output type =
HTTP(the tool also offers RS232 / WG26 / WG34 / RS485 / USB keyboard / USB serial — in any of those the reader beeps locally and never contacts the booth), Server IP = THIS site's booth (park-2 is10.0.10.101;10.0.10.203is the lab — never copy it), server port = the booth's HTTP port (80 behind the prod proxy); "server language" can stay whatever it is (php/jsp/asp/aspx/cgi are all served — the reader GETs/qa/mcardsea.<ext>). - Output prefixes:
QRCode Output Prefix=Q:,Card Output Prefix=K:(channel tagging — a printed clone of a card cannot pass as the card). - Card Input format =
6H(defines the UID shape enrolled; changing it later orphans every card). - Symbologies: QR + Code128 only, minimum decode length ≥ 10, checksums on — otherwise low sun through the striped arm produces phantom 6-digit reads (park-buzi, July).
- Note the serial (
cjihao) — the wizard binds the reader by serial, not by IP.
In the wizard: add the reader with its serial, bind it to the controller relay it sits at
(direction is inherited from the relay). Verify: scan a card — the server log shows
READ serial=… → device=… verdict=… dir=…; the reader beeps twice on accept, once on refuse,
and only after the server's reply (no reply = no beep, the scan still happened).
From the booth, no Windows (2026-10-08): get / set are unicast UDP, so they run on the
booth host over SSH (Python 3 is on every booth; the server container has none):
scp scripts/dingtian_qr.py <booth>:/tmp/ && ssh <booth> python3 -I /tmp/dingtian_qr.py get 10.0.10.7
ssh <booth> python3 -I /tmp/dingtian_qr.py set 10.0.10.7 --output-type 3 # item 2: HTTP mode
get prints every field above by name (output_type, server, server_port, card_input_format,
qr_prefix, card_prefix…). set changes only the fields given and re-sends the rest as read.
Only discover / set-network need the L2 broadcast (run them on the booth, not across Netbird).
Trap: a factory reset or a swapped unit silently loses items 3–5. Re-apply all of them.
Trap (park-2, 2026-10-08): "it beeps, so it works" is false. Enrolling a card failed on both
readers although each beeped. The booth log held zero /qa/mcardsea requests over 21 h and the
capture window saw only the form's own polls: the readers never contact the booth at all. A beep
without a READ line in the log means the reader is not in HTTP mode or points at another
server — fix it on the reader (item 2), nothing in the app or the wizard can. Diagnose in one
command on the booth: docker logs <server> --since 1h 2>&1 | grep -c mcardsea while a card is
presented — 0 = reader-side; then read the reader itself with dingtian_qr.py get (above).
park-2's answer: both readers output_type = WG26 (server 10.0.10.101:3000, JSP, 6H, no
prefixes) — they were left in Wiegand mode at install, so every scan went to a Wiegand line
nobody is listening on. (Port 3000 is fine: the host-net server listens there directly; 80 via
Caddy works too.) Fix = set <ip> --output-type 3 per reader, then re-run the enrolment.
Trap (2026-09-17): two DT-008 units read disjoint card sets. park-buzi's units (H05M…)
read the site's 125 kHz cards and the fresh lab unit (HC002721) reads only 13.56 MHz cards,
although the box leaflet claims both. Batch variant, a dead 125 kHz front end, or a non-EM 125 kHz
card format — unresolved. Rule until it is: test a replacement reader against the site's actual
cards before it ships, and record the site's card technology. Quick sort of a card: an NFC phone
detects 13.56 MHz, cannot see 125 kHz. Details: dingtian-dt008-reader §"Two units, two card
sets".
Identify what a reader can read — before it ships (2026-09-17). Keep a reference kit in the
lab: one known EM4100 125 kHz fob, one known Mifare Classic (M1) card, and a phone with NFC. Tap all
three on the unit with the tool's log pane open (or dingtian-dt008-reader §Bench sink): a line
per tap = that technology decodes. The phone always beeps on a 13.56 MHz unit with a random 08…
id (never a credential, but proves the 13.56 MHz radio). Then tap the site's own cards. Write
the result on the site record next to the serial (reads: EM4100 | M1 | both). Serial families are
only a hint (H05M… read park-buzi's 125 kHz cards, HC… did not); the vendor can confirm from a
serial. A unit that fails the site's cards does not leave the lab.
Parameters per card technology — identical except one field:
| 125 kHz site (park-buzi today) | 13.56 MHz site | |
|---|---|---|
| Card Input format | 6H (what park-buzi's cards are enrolled with — never change on a live site) |
8H preferred: the native UID is 4 bytes, 6H drops one and two cards can collide — confirm 8H on the lab unit before the first enrolment (open-questions #18) |
| Output prefixes | Q: / K: |
Q: / K: |
| Output type / server | HTTP, booth IP, booth HTTP port | same |
| Buzzer | On (the operator hears accept/refuse) | On |
| Symbologies | QR + Code128 only | same |
| Card stock | EM4100 (or whatever the reference test showed) — do not mix | Mifare Classic UID-based; note that a phone is never a card |
A site is one technology: once cards are enrolled the reader batch, the input format and the card stock are frozen together. Migrating means re-enrolling every credential.
The tool's Setting tab (v1.6.5, seen 2026-09-17): Search device lists units by serial; Get
parameter loads one. Network parameter: IP / Netmask / Gateway / DNS1 / DNS2, DHCP (Static IP),
Server address / Server Port / HTTP Server Language, its own Set button. Format parameter:
Output type HTTP, Card Input format (6H), QRCode Output format/prefix/suffix, Card Output
format/prefix/suffix (prefix fields are where Q: / K: go), serial baud/bits greyed out under
HTTP, Low/High Pulse, its own Set. External parameter: Restart interval (12 h), Work mode
(Normal), Buzzer On/Off, Scan code fill light, its own Set. Each group is written by its own
Set button — setting the network and forgetting the format Set is easy. The log pane at the bottom
echoes every card read by the tool (… A238BC), which is the quickest "did the radio see it" check.
The Test device tab is the read monitor. Symbology selection was not found on this tab — locate it
on the Test device tab or in a newer tool before relying on item 5.
3. Hikvision camera (DS-2CD1047G3H-LIU, AcuSense) — ANPR + snapshots
Factory: 192.168.1.64, inactive until a password is set on first boot (browser at that
address or the SADP tool); after activation the login is admin / the password you chose. Site
convention so far: admin / admin123 on the first units (change per site and record it). See
lpr-camera.
By hand, on the camera:
- Activate, set the site IP, disable DHCP. Time: NTP off-site is unavailable — the app re-syncs the camera clock from the booth at every offline→ready edge (clock-integrity).
- Streams: the snapshot the app pulls MUST come from the sub stream (
102) — the main stream's ISAPI snapshot returns 503 instantly, always, on this model. Set the sub stream to the highest resolution the camera allows. Set the sub stream's video encoding to MJPEG — the booth camera tiles stream it live (camera-live-view); with H.264 the tile stays on the snapshot and says why. The102snapshot still returns a JPEG after the switch (measured on the G2 line, 2026-11-17). With the snapshot stream on Sub, its resolution is also the ANPR resolution (MJPEG on the G2: 640×360, 640×480 or 1280×720). - Event push: Event → Motion Detection with the AcuSense Detection Target = Vehicle filter
ON, "Notify Surveillance Center" on, then Alarm Settings → Alarm Server →
http://10.0.10.203/api/devices/hikvision/<deviceId>/event. ThedeviceIdexists only after the wizard assign, so: assign first, then come back to the camera. Digest user/password if the firmware allows it (the wizard shows them). - "Enable Hikvision-CGI" is a different legacy surface — not needed for ISAPI.
- Close the web UI / live view when done. The camera has few connection slots; a browser left open makes every snapshot pull 503 "Device Busy" (lpr-camera §503).
In the wizard: driver hikvision, host, admin password, channel 1, stream = Sub, ANPR on,
bind to the relay at that barrier, alarmPushEnabled on.
Verify, do not assume: drive a car through and look at GET /api/events (or the log) for an
alarm with targetType=vehicle. A camera configured for push that has sent zero alarms is
broken on its side: pull its Diagnose Information; Main Db is broken means a corrupt config
database → factory reset, then redo 1–3 (the Vehicle target filter defaults OFF after a reset).
Point the Alarm Server at a dumb HTTP sink on the laptop if you need to see the verbatim body
(lpr-camera §"auto-enter but not auto-exit").
If the camera is a Dahua (first unit inspected 2026-09-17, dahua-ipc-hfw2549t): factory
192.168.1.108, admin + a password set at first boot, web UI on port 80 (HTTPS off by default
on the bench unit). In the wizard: driver dahua, host, admin password, channel 1 as printed (the
driver sent channel=0 → HTTP 400 until 2026-09-17; fixed). There is no HTTP Alarm Server to
point at the booth: events would be read by the server holding an eventManager.cgi?action=attach
stream (not built yet — a Dahua today gives snapshots + clock sync only, no lane busy/free
and no ANPR bridge), so no "assign first, then go back to the camera" step — but SMD must be set
to Vehicle on the camera. Set the time zone by hand; the app re-syncs the clock from the
booth like it does for Hikvision (the bench unit ran 1 h behind with DST off; NTP is useless on
the isolated VLAN). Five wrong logins lock admin for 5 minutes — check the password with one
curl --digest before assigning.
4. Radar (vehicle presence at the entry barrier)
A dry-contact sensor into a Dingtian input, nothing on the network. Check with the board's input
status (00 query → relays:inputs) whether it idles HIGH or LOW; if it idles opposite the
button, set activeLow on that input in the wizard, or the gate inverts (tickets only when the
lane is empty). It is advisory: it gates the button, it never opens anything (hikvision-radar,
entry-double-press).
5. Printers — three models, one byte stream, different status
All print the same ESC/POS bytes over raw TCP 9100 or USB (/dev/usb/lpN); what differs
is whether the app can see paper/cover state (printer-status-monitoring,
printer-usb-transport). Roles: entry-dispenser outside at the lane, booth-receipt
inside (receipts, subscription cards, Z-reports, and the backup for entry tickets), wash-desk
if the site has a Car Wash (printer-roles-failover). Higher failoverRank = tried first.
| Model | Factory network | Config UI | App driver | Live status |
|---|---|---|---|---|
| k200l-printer (Xprinter/ICS K200L, "POS-80" board; the park-buzi unit) | 192.168.123.100/24, DHCP off |
browser, port 80, no login: Configuration → fixed IP → Save → Restart | k200l |
over LAN: cover / paper / cutter / off-line from /prt_status.htm; over USB: reachability only |
| rongta-printer (RP-series) | not recorded — fill in | status page /prn_stat.htm on port 80 |
rongta |
over LAN: full; USB: reachability |
| Cashino KP-300H | not recorded — fill in | not recorded | escpos (generic) |
reachability only, by design — no trustworthy status source |
Prefer LAN over USB wherever a cable can reach: the booth sees a real amber "cover open, paper
out" while a roll is changed, and the usblp path (udev rule, node renumbering, the park-buzi
"offline after reload" mystery) drops out of the picture. USB needs the appliance's usblp +
udev rule (printer-usb-transport §Provisioning) and the printer shows up as /dev/usb/lpN,
numbered by plug order.
Verify: the wizard's "Test" only probes (opens the port / the device node) — it prints nothing. Print something real: a subscription with a QR credential auto-prints its card and has a Reprint card button; a payment prints a receipt; a wash till prints slips. Check the Cashino's barcode with a real ticket (the KP-300H garbled overflowing barcodes until the geometry fix).
6. Order of work on site
- Address plan on paper; VLAN ports patched; booth PC up with its device-VLAN address.
- Dingtian: factory address → site address (browser) → wire button, radar, barriers.
- Wizard: controllers first (the relay map + inputs); "Relay test" each barrier.
- Readers: tool (IP, server, prefixes, format, symbologies) → wizard (serial, bind) → scan test.
- Cameras: activate → IP → sub stream → wizard assign → Alarm Server + Vehicle target → drive-through test → close the browser.
- Printers: site address → wizard (role, rank) → print a card.
- Walk-through: button + radar → ticket; QR entry then exit; RFID; a subscriber's plate at the camera; pay at the booth → receipt → exit; paper reload on each printer while watching the footer.
- Record in the site record: every IP, serial, camera password, printer model, which relay is which, photos of the labels. Remove the temporary laptop addresses. Log out of every device UI.
7. Reaching the cameras remotely — port forward through the booth host (park-2, 2026-10-08)
park-buzi exposed its two Hikvision web UIs on the site router (park-buzi.msai.al:8081 / :8082,
see lpr-camera). park-2 does the same through the booth host, because its router only
knows the 192.168.1.0/24 side while the cameras live on the device VLAN:
| address | |
|---|---|
| router / internet side | eno1 192.168.1.101, gateway 192.168.1.1, public 91.230.255.154 |
| device VLAN side | eno1 10.0.10.101 (same NIC, second address) |
| Netbird | wt0 100.75.7.237 = park-2.nb.infra |
| entry camera | 10.0.10.9:80 → published as 8081 |
| exit camera | 10.0.10.10:80 → published as 8082 |
Done with iptables on the host (needs root; the admin account has no passwordless sudo).
ip_forward is already 1 because Docker set it. Docker also sets the FORWARD policy to DROP, so
the explicit ACCEPTs are mandatory, and the SNAT is what brings the camera's replies back through
the host (the cameras' gateway is not the booth):
iptables -t nat -A PREROUTING -p tcp --dport 8081 -j DNAT --to-destination 10.0.10.9:80
iptables -t nat -A PREROUTING -p tcp --dport 8082 -j DNAT --to-destination 10.0.10.10:80
iptables -t nat -A POSTROUTING -p tcp -d 10.0.10.9 --dport 80 -j SNAT --to-source 10.0.10.101
iptables -t nat -A POSTROUTING -p tcp -d 10.0.10.10 --dport 80 -j SNAT --to-source 10.0.10.101
iptables -I FORWARD -p tcp -d 10.0.10.9 --dport 80 -j ACCEPT
iptables -I FORWARD -p tcp -d 10.0.10.10 --dport 80 -j ACCEPT
iptables -I FORWARD -m conntrack --ctstate ESTABLISHED,RELATED -j ACCEPT
apt install -y iptables-persistent && netfilter-persistent save # survive reboots
- Reach: from any Netbird peer with a policy to park-2,
http://park-2.nb.infra:8081/(no router change needed). From the internet only once the router forwards 8081/8082 to 192.168.1.101. PREROUTING does not apply to the host's own traffic — test from another machine. - Netbird-only variant: add
-d 100.75.7.237to the two PREROUTING rules; then the public forward can never reach the cameras even if someone adds it on the router. - Undo: the same lines with
-D. ufw, if ever enabled there, also needsufw route allow proto tcp to 10.0.10.9 port 80(and.10). - Why not Docker:
docker run -p 100.75.7.237:8081:80 alpine/socat …would do the same without sudo, bound to the overlay only; the user chose the iptables route. - This is a deliberate hole in network-isolation (camera web UI reachable off the VLAN); the camera's own digest auth is the only gate behind it. Keep the public side off unless needed; prefer the Netbird path.
Gaps to fill next time you hold the hardware
- Factory address and configuration tool of the Cashino KP-300H and the Rongta RP units (both still unknown here).
- Where in
QRCode_v1_6_5.exethe symbologies are selected (the Setting tab has no such field; the IP / server / prefix fields are now described in §2). - The card technology each site uses and which reader batch reads it, on the site record next to the serial; and the result of the EM4100 test on the lab unit.
- Whether the camera activation was done with SADP or the browser at park-buzi, and the per-site camera password location.
- Where the site record lives (a page per site under
wiki/entities/? — park-buzi and park-2 have none yet; the Komodo stack env is the closest thing).
Related: appliance-provisioning · first-run-setup · device-registry · network-isolation · entry-exit-points · dingtian-relay · dingtian-dt008-reader · lpr-camera · hikvision-radar · k200l-printer · rongta-printer · printer-usb-transport · wsl-dev-networking
Booth host firewall: what the device net must reach (2026-10-22)
Found at park-lab (ufw active, rules root-only): the device VLAN could reach ssh but not the app. Devices need, from the device subnet to the booth:
| Port | Who | Why |
|---|---|---|
3000/tcp (PORT) |
dingtian-relay input push, any device push | backendPort() advertises the server's own port, not Caddy's 80 — the push bypasses the proxy. |
| 80/tcp | admins on the LAN | Caddy → operator UI (and /health). |
sudo ufw allow from 10.0.10.0/24 to any port 3000 proto tcp (and 80). Without 3000 the booth's
assign flow succeeds (it configures the device outbound) but every button push then dies with a
timeout — a silent failure. The booth's ufw rule set is not yet captured in
appliance-provisioning; it should be.