The QRCode SDK v1.6.5 settles the reader protocol (supersedes the earlier
serial guess). On each scan the reader HTTP-GETs the host
(/qa/mcardsea.php?cardid&mjihao&cjihao&status&time); the host replies JSON
{data:[{...,status,output}],code:0}. Reply status 1=valid(beep 2x)/0=invalid
(beep 1x); output 0=Access/1=WG26/2=WG34; time syncs the clock. The GET's status
low digit is the direction (1=in/0=out).
Key: the beep/accept is decided by the SERVER REPLY, not locally -- the 'no
beep' during bring-up was a plain-text reply, not a scan failure. Host-in-the-
loop and synchronous. 'Server language' only selects the URL path; transport is
plain HTTP.
New source page qrcode-sdk; updated gee-qr-er80 (protocol resolved), index.
2.8 KiB
type, tags, sources, updated
| type | tags | sources | updated | |||||||
|---|---|---|---|---|---|---|---|---|---|---|
| source |
|
|
2026-06-16 |
Source: QRCode SDK v1.6.5 (GEE/Dingtian QR reader)
Vendor SDK for the QR access reader (gee-qr-er80; also branded Dingtian). Defines the
reader↔server HTTP protocol — the missing piece the datasheet omitted. Files at
QRCode_sdk - QRCode_v1_6_5/sdk/ (config tool QRCode_v1_6_5.exe, demos in C#/PHP/VC++, protocol
docs readme.txt, qrcode_HTTP_GET.txt, VC++/how to.txt). Not copied into raw/ — bulky +
binaries; this summary is the faithful capture. Entity: gee-qr-er80.
The protocol — HTTP GET poll, server replies the verdict
The reader is configured (via the Windows tool) with a server IP/port + "server language"
(JSP/PHP/C#/ASP/CGI — this only selects the URL path, e.g. /qa/mcardsea.php; transport is plain
HTTP either way). On each scan the reader sends:
GET /qa/mcardsea.php?cardid=445D2C&mjihao=1&cjihao=HW256097&status=11&time=1540402036 HTTP/1.0
| Param | Meaning |
|---|---|
cardid |
the scanned QR/barcode data (or card id) |
mjihao |
device id (machine number) |
cjihao |
device serial number |
status |
2 chars: high = valid 1/invalid 0 (reader's own pre-check), low = direction 1=in / 0=out. A 1-char status = fail. |
time |
UTC time |
Server → reader reply (JSON) — this is the access DECISION and drives the beep + output:
{"data":[{"cardid":"<echo>","cjihao":0,"mjihao":1,"status":1,"time":"<utc>","output":2}],"code":0,"message":""}
| Reply field | Meaning (from the C# demo comments) |
|---|---|
status |
1 = valid → buzzer 2×; 0 = invalid → buzzer 1× |
output |
0 = Access, 1 = WG26, 2 = WG34 — output line/format driven on a valid read |
time |
UTC — can sync the device clock |
code |
0 = success |
Implication (explains the "no beep"): the reader's beep/accept is decided by the server's reply, not locally. A non-JSON / missing reply ⇒ no valid feedback ⇒ no beep, even though the scan succeeded. So "no beep" ≠ "didn't scan" — it means the server didn't answer with the verdict.
Integration consequence
This is host-in-the-loop, synchronous: the GET is the access query; our JSON reply is the
decision. So the backend endpoint must decide (valid/invalid + direction) and reply — richer
than a fire-and-forget read. Direction comes from the status low digit. See gee-qr-er80 +
device-input-flow.
Defaults / misc
- Default device IP
192.168.1.99(readme.txt). - Demos: PHP