Files
parking_solution/wiki/decisions/dingtian-vs-mqtt.md
T
julian dd2dd53d7e wiki: H.264 test on park-lab, event-driven refactor decided
- zone-anpr-poc: H.264 instead of MJPEG (load, delay, a car in the zone,
  staff traffic, bad weather); the relay-less test copy is left running
- event-driven-refactor (new): the user's decisions of 2026-11-23, what
  is not decided, what they touch in today's code; waits for the user's
  guidelines
- passage-confirmation: the 2026-11-19 phase order superseded; where the
  video work lives
- vision-hardening, zone-anpr-poc-review: on-screen label read as a
  plate (moved by the user), day-time oversized box, still pause carried
  over
- pointers on vision-service, camera-live-view, lane-presence-and-anpr-entry,
  dingtian-vs-mqtt, entry gates, standing decisions, open questions,
  overview, index

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01RZgP5oZdzvo92Eouc9eRv5
2026-11-23 12:02:18 +01:00

55 lines
2.8 KiB
Markdown

---
type: decision
tags: [parking, decision, devices, transport]
sources: []
updated: 2026-11-23
status: settled
---
# Transport for the Relay Controller: HTTP/UDP now, MQTT parked
**Decision (2026-06-15): use direct HTTP + UDP for the [[dingtian-relay]] controller now. MQTT is
deliberately skipped, but kept on the radar** for when the system scales.
## Options the device supports
The Dingtian relay board speaks several protocols: Dingtian string (UDP/TCP), Dingtian binary
(UDP, optional multicast/password), **HTTP CGI**, **HTTP input-link push** (`input_link_url`),
**Modbus** (RTU/TCP/ASCII), and **MQTT**.
## Why not MQTT (yet)
- **A broker is new infrastructure** on a deliberately **single-purpose hardened appliance**
([[disk-os-hardening]]) — another service to install, secure, supervise, and keep alive.
- **Extra failure mode on the critical path.** Today host→UDP→relay. MQTT inserts a broker on both
control and event paths; if it stalls, the lane stalls — and there are 3 processes to debug, not 2.
- **Doesn't fit [[offline-first]] for this scale.** MQTT earns its keep with *many* devices/consumers
and intermittent links. Here it's **one host + a few devices on one isolated LAN, metres apart** —
request/response control + a single input event, no fleet.
- **The device's MQTT input publish is periodic** ("default every 30 s"), so it's not even a clean
on-press event without relying on unverified on-change behaviour.
## Why HTTP/UDP fits
- **Relay control:** direct **UDP string protocol** (port 60001) — `11`=relay1 on, `21`=off,
`T1`=toggle, `11*`=jog/pulse. No deps, no broker.
- **Input/button events:** the device's **`input_link_url`** can **HTTP POST to the host backend
when an input fires** — real push, device calls our existing Fastify server directly, no broker.
(Polling `00` status over UDP every ~50 ms is the self-contained fallback.)
- Fewest moving parts; matches the local same-origin model already in use.
## When to revisit MQTT
If the system grows to **many lanes / many controllers**, or multiple subsystems (LPR, payment,
signage) all need to share events, a broker becomes a worthwhile central event bus. That aligns
with the [[autonomous-direction|unmanned]] roadmap at multi-lane scale — re-evaluate then. Until
then, direct HTTP/UDP wins on simplicity and reliability.
## The condition is met (2026-11-23)
The user decided a bus between the vision side, the server and the booth screen, as part of an
event-driven refactor of the repository ([[event-driven-refactor]]). That is the case named
above: several subsystems sharing events. Which bus is not decided, and nothing here says the
relay controller moves onto it. The objections above (new infrastructure on the appliance, one
more thing on the path that opens the barrier) still want an answer in that plan.