The controller editor mixed outputs and inputs in one flat "Relays" block — relay direction, the entry-button terminal, and the presence/radar terminal all on the same row, with the lamp orphaned below. Reorganize into two labelled sections: - Outputs — relays (barriers + lamp): relay # + direction, the button-light relay, and "Pulse open (ms)" (a relay hold-time, NOT an input setting — answers a recurring confusion). - Inputs — terminals (button, sensor): per entry relay, the button + presence/radar terminals (kind, active-low) and cooldown, each labelled "For relay N", plus the board-wide "Inputs idle HIGH". UI-only: storage stays config.relays[] (+ config.buttonLight), so saved booth configs keep working with no migration. pulseMs/inputRestingHigh are pulled out of the generic field loop and rendered in their section. i18n parity (sq + en). Also passes the device id to testDevice() so an edited device's stored relay password re-merges on Test connection (pairs with the secure-merge server change). Claude-Session: https://claude.ai/code/session_01Xcm6ikLgGoCxxHrxtjkk5V